Search results for "Valsalva maneuver"
showing 6 items of 6 documents
Analysis of Internal Jugular Vein Insufficiency—A Comparison of Two Ultrasound Methods
2006
Abstract Jugular venous valve insufficiency is a contributing factor to different pathologic conditions. For assessment of insufficiency, two ultrasound techniques have been developed, that are based on very different methodology (direct Doppler assessment versus air contrast ultrasound venography [ACUV]). This study was conducted to compare these two methods to improve comparability of existing studies and diagnostic accuracy in future studies. The function of 40 valves was determined in 20 individuals during a Valsalva maneuver. For direct Doppler assessment, valvular competence was assessed on basis of Doppler recordings, following recently established criteria. Valvular insufficiency in…
Cardiovascular autonomic neuropathy in type 1 diabetic patients with and without peripheral neuropathy.
1998
One hundred Type 1 diabetic patients (54 men, 46 women) mean age 28.9 +/- 8.4 years, were selected from among individuals referred to our hospital, with no previous diagnosis of diabetic chronic complications including diabetic neuropathy. After clinical and physical examinations, subjects were divided into two groups: with (n = 37) and without (n = 63) peripheral neuropathy. The percentage of subjects with cardiovascular autonomic neuropathy (AN), diagnosed by positive results to at least two of the five cardiovascular tests (Valsalva ratio, EI ratio, 30/15 ratio, blood-pressure response to standing up and handgrip test), was 40%: 72.9% in the group with peripheral neuropathy and 20.6% in …
The PFO anatomy evaluation as possible tool to stratify the associated risks and the benefits arising from the closure
2010
Aims According to the current guidelines, the patent foramen ovale (PFO) is still considered a qualitative factor and, as a consequence, its closure is recommended just on the basis of its ‘presence’. Methods and results In the year 2008, we evaluated 25 patients (mean age 62.7) with acute cerebrovascular event and 92 patients (mean age 27.3) suffering from migraine with aura. No PFO was reported in 79 patients. A venous-to-arterial circulation shunt had been shown in 38 patients (29 subjects with migraine and 9 subjects with prior stroke). According to the number of microbubbles arrived during the Valsava manoeuvre, we found: 25 small PFO, 6 moderate PFO, and 6 severe PFO. In the baseline …
Involvement of Jugular Valve Insufficiency in Cerebral Venous Air Embolism
2007
Background. Cerebral venous air entrapment is a rare finding on cranial computed tomography (CT) scan. Peripheral air embolism is discussed as a potential cause. However, the mechanism of retrograde passage through internal jugular valves and veins is unclear. Case Report. The case of a patient is reported, who had air entrapment in the left cavernous sinus. Prior to CT scanning, a peripheral intravenous line had been placed. Ultrasound revealed excessive insufficiency of the left internal jugular valve. To further study the mechanism of embolism, an echo contrast agent was injected into the cubital vein. A Valsalva maneuver resulted in retrograde transition of microbubbles across the insuf…
Differences and Similarities in Neuropathy in Type 1 and 2 Diabetes: A Systematic Review
2021
Background: Diabetic neuropathy is defined as the dysfunction of the peripheral nervous system in diabetic patients. It is considered a microvascular complication of diabetes mellitus. Its presence is associated with increased morbidity and mortality. Although several studies have found alterations at somatic motor, sensory levels and at the level of autonomic nervous system in diabetic patients, there is not a systematic approach regarding the differences in neuropathy between the major variants of diabetes, e.g., type 1 and 2 diabetes at both neurological and molecular level. Data sources: we systematically (Medline, Scopus, and Cochrane databases) evaluated the literature related to the …
Regional Lung Blood Perfusion Measured With Laser Doppler Method During Body Position Change, Valsalva Manoeuvre and Cardiopulmonary Bypass
2008
Regional Lung Blood Perfusion Measured With Laser Doppler Method During Body Position Change, Valsalva Manoeuvre and Cardiopulmonary Bypass Methodological approaches to investigate local regulatory mechanisms of lung blood supply in humans are restricted. We tried a new approach using laser Doppler technique. During bronchoscopy, an angled laser Doppler flow probe was introduced through a biopsy channel and wedged into small bronchus. Laser light penetrated the wall of small bronchus and was reflected from blood cells running through neighbouring capillaries. Regional blood perfusion changes were recorded during body position change from vertical to supine and back to vertical, while perfor…